EverStar Group brings you over 13 years of specialized manufacturing excellence in Concrete Retarder Chemical solutions. Our Factory-direct supply model, backed by 5,000+ tons on-site inventory and 99.5% on-time delivery performance, ensures you never face project delays. Our retarder formulations achieve precise setting time control under challenging conditions—whether you're managing mass concrete pours in 35°C heat or coordinating multi-stage foundation work across extended timelines. With purity ≥98.0%, chloride content ≤0.05%, and full compliance with ASTM C494 Type B/D and EN 934-2 standards, our product delivers predictable hydration delays without compromising your 28-day compressive strength targets.

You need reliability when concrete placement windows stretch beyond standard timeframes. Our formulation uses refined hydroxycarboxylic acid compounds that target the C3S and C3A hydration phases with surgical precision.
Here's what sets our product apart:
Consistent Performance Across Cement Types
We've engineered our retarder to work seamlessly with ordinary Portland cement, blended cements containing fly ash, and even high-sulfate-resistant varieties. You won't experience the unpredictable results common with generic formulations.
Temperature-Adaptive Dosing
Our technical team provides calibrated dosing charts for ambient temperatures ranging from 20°C to 40°C. At 0.03%–0.15% dosage (by cement weight) under 20–35°C conditions, you'll achieve 2–7 hours of controlled retardation.
Strength Development You Can Trust
When used at equal slump conditions, the slight water reduction effect enables 28-day compressive strength reaching 110%–120% of your control mix. If you maintain the same water-to-cement ratio while adding our retarder, early strength shows a minor reduction, but 28-day values match your baseline perfectly.

| Parameter | Specification |
|---|---|
| Appearance | White crystalline powder |
| Purity | ≥98.0% |
| Loss on Drying | ≤0.5% |
| Chloride Content | ≤0.05% |
| Sulfate Content | ≤0.05% |
| Heavy Metals (Pb) | ≤10 ppm |
| Reducing Substances | ≤0.5% |
| pH (10% solution) | 6.2–7.8 |
| CAS Number | 527-07-1 |
| Specific Gravity | 1.05–1.25 |
| Standards Compliance | ASTM C494, EN 934-2 |
| Certifications | ISO 9001, REACH |
Note: Product specifications may be adjusted during product iteration and optimization. Please submit your inquiry to us for the latest data and official COA documents.
Where You'll Use This Solution?
Mass Concrete Projects
When you're pouring dam establishments, bridge docks, or flatboat establishments surpassing 1 meter thickness, warm of hydration gets to be your adversary. Our retarder amplifies the acceptance period, permitting inside warm to scatter steadily. This anticipates warm breaking and dispenses with cold joints between progressive lifts—critical for auxiliary keenness in load-bearing elements.
Hot Climate Construction
In Center Eastern work locales or summer pours where temperatures surpass 30°C, concrete loses workability inside 45 minutes. Our definition keeps up droop for 3–5 hours, giving your team satisfactory time for arrangement, solidification, and wrapping up without relinquishing surface quality.
Long-Distance Transit
Urban construction sites often sit 60–90 minutes from batching plants. Traffic delays can turn fresh concrete into hardened waste. By incorporating our Concrete Retarder Chemical at the plant, you preserve plasticity throughout the journey, reducing rejected loads and material waste.
Decorative Exposed Aggregate
Apply our product as a surface retarder on horizontal slabs. It delays only the top 3–5mm of cement paste setting, allowing you to pressure-wash the surface 18–24 hours later to reveal pristine aggregate textures for architectural finishes.

Standard Dosage Range
Add 0.03%–0.15% by weight of cement. At 20–25°C, expect 2–4 hours of retardation. At 30–35°C, increase to 0.10%–0.15% for the same effect.
Understanding Overdose Consequences
Many suppliers claim overdosing "only delays setting without affecting final strength"—this is dangerously misleading. Here's the reality:
Always conduct trial mixes when changing cement brands or aggregate sources.
Each bunch taking off our office experiences thorough testing:
Chemical Analysis
We confirm strong substance through gravimetric investigation and affirm pH solidness over generation parts. Our in-house lab runs particle chromatography to ensure chloride and sulfate levels remain underneath determination limits.
Performance Verification
Using ASTM C403 infiltration resistance testing, we degree both starting and last set times against control tests. Compressive quality testing at 7 and 28 days (ASTM C39) guarantees your auxiliary necessities will be met.
Compatibility Screening
Before shipping custom orders, we test compatibility with your indicated cement sort and any polycarboxylate ether (PCE) superplasticizers you're utilizing. A few combinations can open up or decrease water-reducing effects—we distinguish these intelligent some time recently they reach your work site.

Factory-Direct Pricing
As the producer, we dispose of wholesaler markups. You get 20%–40% taken a toll investment funds compared to imported options without relinquishing quality.
Flexible Arrange Quantities
Whether you require 500kg for a trial extend or 20-ton holder loads for yearly supply understandings, our 5,000-ton stock capacity guarantees prompt availability.
Technical Support That Understands Your Challenges
Our chemical engineers have worked on-site in dam development, high-rise ventures, and precast operations. When you contact info@cneverstar.com, you're talking with experts who get it the distinction between 'retardation' and 'extended set'—and how to dodge the latter.
Global Coordinations Network
We've dispatched the item to 50+ nations with a 99.5% on-time record. Our group handles send out documentation, traditions coordination, and holder optimization to get items to your distribution center without delays.

Q: Can I utilize this with air-entrained concrete?
A: Yes, but screen discuss substance utilizing ASTM C231 testing. A few details may somewhat increment entrainment levels—our specialized group will direct measurement alterations if needed.
Q: What happens if temperatures drop amid curing?
A: Cold climate underneath 15°C can expand hindrance times unusually. We prescribe lessening dose by 30%–50% and actualizing protects curing covers to keep up concrete temperature over 10°C.
Q: Is it congruous with silica smolder or fly fiery remains mixes?
A: Completely. Our item works viably with supplementary cementitious materials (SCMs). The diminished alkalinity in mixed cements may require slight measurement increases—typically an extra 0.01%–0.02%.
Q: How ought to I store this product?
A: Keep holders fixed in a dry environment underneath 30°C. Appropriately put away, our powder detailing keeps up full adequacy for 12 months. Dodge coordinate daylight and dampness exposure.
Q: Will this avoid my concrete from ever coming to full strength?
A: No. This is a determined myth. When dosed accurately, our retarder really makes strides the crystalline structure of solidified cement glue. Numerous clients report denser concrete with upgraded toughness compared to untreated mixes.
Q: What if I require a custom impediment profile?
A: Our R&D lab can create custom-made definitions inside 24 hours. Whether you require 10-hour workability for complex building pours or exact 90-minute delays for precast operations, we'll make a arrangement coordinated to your correct necessities.
EverStar Group's Concrete Retarder Chemical solves the timing challenges that derail construction schedules. Contact Us at info@cneverstar.com or speak with your dedicated account manager about volume pricing for upcoming projects.